Calefaciens Equipment
Praecipua structura Resistentiae temperaturae detectionis Transmitter comprehendit convenientiam interfaciem, ambitum mensurae, conversionem digital/analogam, communicationem interfaciem, materiam testam, etc. Resistentia temperatura sentiendi transmittere plerumque interfaces quae compatiuntur cum sensoriis caliditatis generibus, sicut platini resistentia temperatura. sensoriis (RTDs), thermocouplis, etc. In medio ambitus mensurae dedicatae instructa est ad signa sensoria legendi et processus signo faciendos. Solent hi circuitus ambitus amplificatores, filtra, ambitus compensatio includere, etc. ut firmitatem ac diligentiam signum mensurae curet. Resistentia temperaturae sentiendi transmitters solent instructi cum convertente digitali vel analogo ad convertendum analog signum a sensore generatum in signum digitale ad digitizationem vel communicationem cum systemate digitali. Ut cum externa potestate systemata vel vigilantia systemata communicent, resistentia temperaturae sentiendi transmitters vexillum communicationis socialis plerumque habere consuevit. Thestatio plerumque metallica vel materia plastica facta est et corrosionem bonam habet resistentiam et facultatem anti-incessionis ad defendendum ambitum internum ab ambitu externo.
Product Parameter
Morbi condimentum
| Input | |
| Input signum | Resistentia temperatura detector (RTD), thermocouple (TC) |
| Frigus coniunctas ultricies temperatus scope | -20~60℃ |
| Compensation praecisione | ±1℃ |
| Output | |
| Output signum | 4...20mA(duo-filum) |
| Onus resistentia | RL≤(Ue-12)/0.021 |
| Output current superioris et inferioris modum redundantiam terrorem | IL=3.8mA、IH=21mA |
| Potentia copia | |
| Supple voltage | 12...40VDC |
| Alii parametri | |
| Temperatus summa | ≤0.03%FS/℃ |
| Responsum tempus | Pervenire ad XC% ad valorem pro 1s |
| Usus environmental temperatus | -40~80℃ |
| Repono temperatus | -40~100℃ |
| Installation area | Top Paperback institutionem |
Input genus et tradenda praecisione
| Type | range mensuræ | Minimum range measurement | Conversio accurate |
| Pt100 | -200~850℃ | 20℃ | ± 0.1% range or ± 0.2℃ |
| Cu50 | -50~150℃ | 20℃ | ± 0.1% range or ± 0.2℃ |
| B | 400~1800℃ | 500℃ | ± 0.1% range vel ± 1.5℃ |
| E | -100~ 1000℃ | 50℃ | ± 0.1% range or ± 0.5℃ |
| J | -100~1200℃ | 50℃ | ± 0.1% range or ± 0.5℃ |
| K | -180~1372℃ | 50℃ | ± 0.1% range or ± 0.5℃ |
| N | -180~1300℃ | 50℃ | ± 0.1% range or ± 0.5℃ |
| R | -50~1768℃ | 500℃ | ± 0.1% range vel ± 1.5℃ |
| S | -50~1768℃ | 500℃ | ± 0.1% range vel ± 1.5℃ |
| T | -200~ 400℃ | 50℃ | ±0.1% range or ±0.5℃ |
PRODUCTUS CATEGORY
shipment
customers praebet cum qualitate et translationem tutum.
Effective calor * * * * * *is serie The calor translatio efficientiam a * Adapter Heater valde pendet adscendens m...
READ MOREEt Sinton Flante immersionem calefacientis In specie disposito ad occursum postulantes calefactio requisitis industries ut P...
READ MORE1. Industria consummatio et efficientiam In SPECTATIO in an Immersionem calefacientest Plays a significant munus in a...
READ MOREAestus translatione machinationes Facultatem Pipeline calefaciente Ad ponere in desideravit temperatus in pipelines ...
READ MOREConsilium fundamentale Oleum Circulationis Calefaciens revolvitur circa facultatem suam oleum calefactum continue circulare per syste...
READ MORE